*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 9
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
35*
Left peltier current is too
high
Current sensing circuit
situation
ON mode:
current above 4.65 A for
more than 0.5 sec.
STANDBY mode:
current above 2.1 A for
more than 0.5 sec.
Automatically, when
current is within limits
On error, the left
current is
switched off, but
every 2 minutes
a sample is
taken to see if
the current is
within limits
1. Air inlet filter soiled
2. Wiring incorrect or
connections defective
3. Peltier element
defective
4. PCB B not inserted
correctly in the rack or
defective
1. Clean or replace air inlet
filter
2. Check wiring or replace
connections (see
chapter 5K)
3. Replace peltier element
(see chapter 5K)
4. Insert PCB B correctly or
replace it (see chapter
5K)
10
36*
Right peltier current is
too high
Current sensing circuit,
situation
ON mode:
current above 4.65 A for
more than 0.5 sec.
STANDBY mode:
current above 2.1 A for
more than 0.5 sec.
Automatically, when
current is within limits
On error, the
right current is
switched off, but
every 2 minutes
a sample is
taken to see if
the current is
within limits
1. Air inlet filter soiled
2. Wiring incorrect or
connections defective
3. Peltier element
defective
4. PCB C not inserted
correctly in the rack or
defective
1. Clean or replace air inlet
filter
2. Check wiring or replace
connections (see
chapter 5K)
3. Replace peltier element
(see chapter 5K)
4. Insert PCB C correctly
or replace it (see
chapter 5K)
10
37**
NO SI message
(combined peltier error:
33 and 34 or 36 or
35 and 34 or 36)
only shown in User
Interface screen
Software combination
Automatically when both
errors have been reset
-
-
60
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...