*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 24
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
104
Credit medium error
When one of the
following conditions
appear:
1. Init of card (system)
fails
2. Revalue of card fails
3. Invalid payment media
(1)
4. Payment media
jammed
5. Unable to restore
money
6. MDB changer: No
credit
7. MDB changer: coin
jam
8. MDB bill: Bill removed
Automatically, when the
problem has been solved
or
by restarting the system,
when the problem has
been solved.
Similar errors
(see column
‘Set condition’)
generated by
different
payment
systems are
combined and
displayed as
error 104.
Further info
concerning the
error must be
found in the
payment system
manual/menu.
The respective payment
system generates one of
the mentioned errors.
Check the payment system
by means of the respective
payment system manual.
100
120
Drink selection unknown
or not possible
Displayed after a wrong
or impossible drink
selection (combination of
pre-selection and drink
selection). Only used
internally (screen is
shown for 2 seconds)
No reset is necessary.
The error is
shown for 2
seconds as a
warning. It is not
set/reset.
1. Pre-selection
combination is not
allowed
2. Selected default
selection and recipe
conflict.
3. One of the drink
settings is wrong
(volume too low,
ingredient not found,
strength out of
bounds, flow type
wrong, rapid flow not
allowed, cold water
not allowed)
1. Select a other pre-
selection
2. Change the drink setting
of that button
3. Change the drink setting
of that button
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...