Functions - cooling system
Monitoring – Peltier current
•
The intensity of the Peltier current is regis-
tered by the control system by means of
voltage via a measuring resistor (0.1 ohm;
on the control system board).
•
In order to prevent consequential damage
in the case of an imminent short circuit of
the Peltier element, the cooling system is
switched off:
-
if the electric current flows constantly
exceeding 6 A for more than approx. 1
sec. (message error 35, 36)
or
-
if the current flows constantly below
approx. 1.7 A for more than 1 sec.
(message error 33, 34).
The cause of this error can lay with the
missing heat dissipation by the heat sink
(the heat sink is completely soiled or the
fan is standing still).
With an increasing heat sink tempera-
ture, the current through the Peltier
element decreases.
•
Normally, (i.e. in a stable cooled state), a
Peltier current flows within a range of
2.7–3.1 A. In the first minute following an
interruption of electric current, however, the
electric current can be up to 15% higher.
Cafitesse 700 - Functions - cooling system
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...