*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 16
Errors hygiene system
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
70**
Flushing required within
XX hours xx minutes
(preset due period, e.g. 4
hours)
Software timers
Only when FLUSH has
been executed
successfully, NOT by
power up or
ON/OFF/CLEAR switch
No service
interface
message
-
-
2
0
71*
Flushing was not
executed
Software timers
Only when FLUSH has
been executed
successfully, NOT by
power up or
ON/OFF/CLEAR switch
-
Reset by executing
FLUSH, adjust CLEANING
MOMENTS and/or CLOCK
SETTINGS if required
70
72**
Cleaning and flushing
required within XX hours
xx minutes (preset due
period, e.g. 4 hours)
Software timers
Only when CLEAN &
FLUSH has been
executed successfully,
not by power up or
ON/OFF/CLEAR switch
No service
interface
message
-
-
2
1
73*
Cleaning and flushing
was not executed
Software timers
Only when CLEAN &
FLUSH has been
executed successfully,
not by power up or
ON/OFF/CLEAR switch
-
Reset by executing
FLUSH, adjust CLEANING
MOMENTS and/or CLOCK
SETTINGS if required
71
74*
Water throughput limit
exceeded
Software timers plus
calculation
Only when water filter
counter has been reset,
NOT by power up or
ON/OFF/CLEAR switch
Does not block
drink delivery
1. Water filter defective
2. Water throughput
counter not reset
1. Replace water filter
2. Check wiring or replace
connections (see
chapter 5K)
10
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...