*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 2
Errors water system
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
10*
Overboil safety has been
tripped
21
Temperature limiter
(clixon) has been
activated:
Temp
80
°C(1
76
°F)
±3
K
Automatically, when
hardware detects, that
safety has been reset
manually
1. Overboil safety
defective
2. Heating or safety
relays defective
3. Wiring incorrect or
connections defective
4. PCB A not inserted
correctly in the rack or
defective
1. Check temperature
sensor, reset overboil
safety
2. Replace heating or
safety relays
3. Check wiring or replace
connections (see
chapter 5K)
4. Insert PCB A correctly or
replace it (see chapter
5K)
120
11*
Boiler water level is too
low
Low level sensor = dry
for several seconds
during normal operation
Automatically, when low
level sensor detects
water
1. Water supply tap not
open or blocked
2. Water pressure is too
low
3. Inlet valve is defective
4. Overflow hose is
blocked
5. Low level sensor
defective
6. Wiring incorrect or
connections defective
7. PCB A not inserted
correctly in the rack or
defective
1. Open or clean tap
2. Check water pressure
(see chapter 2)
3. Replace inlet valve (see
chapter 5A)
4. Check and clean/
replace overflow hose
5. Replace low level
sensor
6. Check wiring and
replace connections
7. Insert PCB A correctly or
replace it (see chapter
5K)
120
12*
Boiler level sensors not
detected
10, 11
13, 14
15, 16
Overflow safety active (=
connector not detected)
Automatically, when
hardware detects the
contact bridge
1. Wiring incorrect or
sensor connections
defective
2. PCB A not inserted
correctly in the rack or
defective
1. Check wiring or replace
sensor connections (see
chapter 5K)
2. Insert PCB A correctly or
replace it (see chapter
5K)
120
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...