OP000440
6-5
Troubleshooting
TRAVEL SYSTEM
Working mode selector does not
work
Blown fuse.
Replace fuse.
Connector failure.
Replace connector.
Wiring harness damaged.
Repair or replace as required.
e-EPOS controller failure.
Replace as required.
Problem
Cause
Remedy
Problem
Cause
Remedy
Travel motion does not function
Axle failure
Repair
Activate the emergency actuation
Deactive the emergency actuation
Electric accelerator pedal failure
Repair or exchange
Transmission control valve failure
Repair or exchange
Transmission failure
Repair
Center joint leaking
Repair or exchange
Brake will not release
Repair
Travel motor failure
Repair
Hydraulic accelerator valve failure
Repair
Wrong pilot line connection
Repair
Transmission control pressure set
too low
Repair
Forward, reverse solenoid valve
failure
Repair or exchange
Travel speed is too low
Control valve set pressure too low
Reset
Travel motor relief set pressure
low
Reset
Brake is slightly engaged
Repair
Noise from transmission
Low gear oil
Refill
Deterioration of gear oil
Replace
Internal parts worn
Repair or exchange
Gear or bearing damaged
Repair or exchange