OP000530
Inspection, Maintenance and Adjustment
4-20
1.
Remove dipstick (1, Figure 24) and wipe the oil from the
dipstick with a cloth.
2.
Insert dipstick (1, Figure 24) fully into dipstick tube.
3.
When dipstick is pulled out, oil level must be between
"HIGH" and "LOW" marks on dipstick.
NOTE:
If oil is above "HIGH" mark on dipstick, some
must be drained to proper level.
4.
If the oil does not reach the "L" mark on the dipstick, add oil
through fill port (2, Figure 24).
5.
If the oil level exceeds the "H" mark on the dipstick, open
cap (3, Figure 26) of drain valve and connect hose (4) to
the valve. Drain the excessive oil into a suitable container.
NOTE:
Dispose of drained fluids according to local
regulations.
FG006599
1
2
Figure 24
L
H
FG000419
Figure 25
FG006600
4
3
Figure 26
Содержание DX190W
Страница 2: ......
Страница 71: ...OP000528 2 3 Operating Controls ...
Страница 128: ...OP000528 Operating Controls 2 60 CD Player Optional AST DIR FG000109 Figure 135 ...
Страница 196: ......
Страница 292: ...OP000530 Inspection Maintenance and Adjustment 4 96 ...
Страница 304: ...OP000440 6 8 Troubleshooting ...