OP000530
Inspection, Maintenance and Adjustment
4-48
Change Pilot Filter
NOTE:
Change pilot filter after first 250 hours of operation or
rebuild, and every 1,000 hours thereafter.
NOTE:
If pilot filter clogged warning light (Figure 85) on
instrument panel comes "ON" the pilot filter must be
serviced.
1.
Position the machine on firm, level ground. Lower the front
attachment to the ground and shut down engine.
2.
Loosen the breather cap (1, Figure 83) slightly to release
the internal pressure.
3.
Locate pilot system filter assembly. See Figure 86.
4.
Unscrew canister (5, Figure 87) and remove O-ring (3) and
filter cartridge (4).
NOTE:
The canister will be filled with oil. Use caution
when removing this assembly.
5.
Insert a new filter cartridge and O-ring. Apply a small
amount of oil around the entire O-ring and install the
canister assembly onto the filter head (1, Figure 87).
NOTE:
Used filter should always be disposed of
according to local regulations.
6.
After changing pilot filter, vent air from pump and check
level of hydraulic oil tank.
Figure 85
C
H
C
E
F
H
E/G SPEED
1700
RPM
FG000763
02/05 [MO] 11:30
Figure 86
FG006684
WARNING!
The hydraulic oil will be hot after normal machine
operation.
Allow the system to cool down before changing pilot filter.
Figure 87
FG000323
2
1
3
4
5
Содержание DX190W
Страница 2: ......
Страница 71: ...OP000528 2 3 Operating Controls ...
Страница 128: ...OP000528 Operating Controls 2 60 CD Player Optional AST DIR FG000109 Figure 135 ...
Страница 196: ......
Страница 292: ...OP000530 Inspection Maintenance and Adjustment 4 96 ...
Страница 304: ...OP000440 6 8 Troubleshooting ...