XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
49
Alarm Transmission Systems and Equipment EN 50136-1 and -2
Net and Cell Test Days in Communication must be set to 1.
Panel events are stored in non-volatile memory. Part number: Atmel AT24C256C-SSHL-T. The Display Events section
of the User Menu is a read-only function.
This equipment shall be installed in accordance wit local, national, and European requirements and regulations
for attachement to, establishment, and termination of connection and transmission via public telephone and data
networks and/or the regulations for transmission via the use of radio, power distribution systems, or cable TV
distribution systems.
Messages are sent to the central station using the pass-through method. Messages are processed and sent as they are
received.
Premises Wifi network must meet the requirements for 802.11b or higher. A communication test message must be sent
to verify sufficient network capacity before the system is commissioned.
The XTLplusINT uses 4-digit user codes for a total of 10,000 possible combinations.
Access to the SPT is protected by a 4-digit service user code and a 4-digit lockout code for a total of 100,000,000
possible combinations.
Failure of the ATP is indicated at the keypad by the CELL –TROUBLE or NET –TROUBLE messages
The network interface is monitored by the Wifi icon on the keypad. Absence of this icon indicates loss of wifi
connection
A valid User Code is required to be entered to display the Status List. The display will time out in 60 seconds with no
key presses. A valid User Code will be required to be entered again to view list.
The keypad is disabled for 90 seconds when three invalid codes are entered in a 60 second period
In System Options, Closing Check must be ON when using Auto Arm. When arming, Closing Time! is displayed for
10 minutes and the keypad sounds. Bad zones are processed according to the Bad Zones programming in Area
Information. Other troubles are automatically overridden.
Features outside the scope of EN50131 may be configured by an acess Level 3 user.
The XTLplusINT contains no user serviceable parts.
The XTLplusINT draws an average of 95 mA from the battery when AC power is lost. The 3500 mAh battery
(XTL+BAT3500) is required for Grade 2 applications.