Digital Monitoring Products
XTLplus International Series Installation and Programming Guide
14
Send Communication Trouble
Enable communication fail notification by selecting YES at COMM TRBL. Select NO to
disable. Default is
YES
. If set to yes, Comm Troubles will be logged in panel events.
When COMM TRBL is YES and the panel detects a failure of communication, the panel
sends an S72 (Comm Trouble) message through a backup communication method with
notification of the failure. If both primary and secondary methods of communication
fail, then two S72 messages will be sent via the third communication method, if
programmed. When communication is restored, the panel sends an S73 (Comm
Restored) message through the primary communication.
If the primary or secondary communication type is CELL, S72 and S73 messages include
the cell signal strength as a -dBm value.
First Cell APN
Enter the first APN (Access Point Name). This allows an access point for cellular
communication and is used to connect to a DNS network. The APN may contain two
lines of 16 characters to equal 32 characters. Default is set to
SECURECOM400
.
Receiver 1 Programming
Allows you to set the options for the first receiver the panel attempts to contact when
sending reports. The XTLplusINT supports communication to two receivers.
Alarm Reports
YES
enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and
System Recently Armed reports to be sent to this receiver. Default is
YES
.
Supervisory/Trouble Reports
YES
enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to this receiver. Default is
YES
.
Opening/Closing and User Reports
YES
enables Opening/Closing, Code Changes, and Bypass reports by user to be sent to
this receiver. Default is
NO
.
Test Report
Enter
YES
to enable the Recall Test report to be sent to this receiver.
First IP Address
Enter the first (primary) IP address where the panel sends network or cellular
information. Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250 as 192168000250. The periods display automatically.
The message is sent using first Cell APN and the first IP Address. If no acknowledgment
is received, first Cell APN and the second IP address are used, followed, if needed, by
second Cell APN and first and second IP addresses, respectively.
First IP Port
Enter the first IP port number to be used in conjunction with the first IP Address. The
IP port identifies the port used to communicate messages to and from the panel. The
default IP Port setting is
2001
.
Second IP Address
Enter the second (secondary) IP address where the panel sends network or cellular
information. Enter all 12 digits and leave out the periods. For example, enter IP address
192.168.0.250 as 192168000250. The periods display automatically.
Second IP Port
Enter the second IP port number to be used in conjunction with the second IP address.
The IP port identifies the port used to communicate messages to and from the panel.
The default IP Port setting is
2001
.
TEST TIME
COMM TRBL NO
YES
FIRST CELL APN
SECURECOM400
RECEIVER 1 PROG
ALARM NO
YES
SPV/TRBL NO
YES
O/C USER NO
YES
TEST RPT NO
YES
FIRST IP ADDR
000.000.000.000
FIRST IP PORT
2001
SECOND IP ADDR
000.000.000.000
SECOND IP PORT
2001