Digital Monitoring Products
XTLplus International Series Installation and Programming Guide
36
Pet Immunity
This option displays for the 1122INT Wireless PIR Motion Detector. Select whether or not
to enable pet immunity. Selecting YES allows pet immunity for animals up to 55 pounds.
Next Zone
Select YES to return to the ZONE NO: - option to program a new zone. Select NO to
display the Alarm Action option.
1144INT Series Key Fobs
Only zones 51-54 or 61-64 can be programmed as 1144INT Series Key Fob zones. Refer to the 1100INT Series Key Fob
Programming Sheet (LT-0706INT) and the 1144INT Series Key Fob Install Guide (LT-1449INT) as needed.
To operate arming and disarming properly, the Key Fob should be assigned to a User Number with appropriate area
assignments, however, the User Number does not have to exist at the time the Key Fob is programmed. The User
Number can be added at the User Menu later by the User.
The following programming continues from when Key Fob YES is selected.
Key Fob User Number
Enter the User Number used to identify the key fob user and their arming and disarming
authority. Default is
blank
. User number range is 1 to 99
Displays when the User Number entered does not exist in User Code programming. The
key fob can be added, but the user must eventually be added to cause the key fob to
operate.
Key Fob Serial Number
Enter the eight-digit serial number found on the wireless device.
When a serial number is already programmed, the zone number displays.
Key Fob Supervision Time
Press any top row key to select the supervision time required for the key fob zone. Press
CMD
to accept the default time. Default is
0
.
Press the select area under the required number of minutes. The key fob must check in
at least once during this time or a missing condition is indicated for that zone. 1144INT
Series key fobs automatically checkin based on the supervision time selected for the
wireless zone, no additional programming is needed. Zero (0) indicates an unsupervised
transmitter. When the panel is reset the supervision timer restarts for all wireless zones.
Number of Key Fob Buttons
Enter the number of buttons (1, 2, or 4) on the key fob being programmed. Default is
four buttons
.
If the key fob is a one-button model, programming continues at the Button Action
section. Default button assignment for one-button key fobs is a Panic Alarm (PN) with
no output assigned.
Key Fob Button Selection (Four Buttons)
This option only displays if the key fob being programmed is a four-button model. Press
the select key under the key fob button to program. The following list identifies the
default button assignments:
TOP
Arming with areas 1, 2, and 3 assigned
BTM
Disarming with areas 1, 2, and 3 assigned
LFT
Panic Alarm (PN) with no output assigned
RGT
Arming with Area 1 assigned
Key Fob Button Selection (Two Buttons)
This option only displays if the key fob being programmed is a two-button model. Press
the select area under the key fob button to program. The following list identifies the
default button assignments:
WIRELESS PIR PET
IMMUNITY: NO YES
NEXT ZONE NO YES
KEY FOB USER
NUMBER: XXXX
USER XXXX
NOT IN USE
TRANSMITTER
SERIAL#: XXXXXXXX
TRANSMITTER
SUPRVSN TIME: 0
SELECT MINUTES:
0
60 240
NO. OF KEY FOB
BUTTONS: X
BUTTON:
TOP BTM LFT RGT
BUTTON:
TOP BTM