XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
27
BELL OPTIONS
Bell Options
This section allows you to program the panel bell output functions. If using the Model
1135INT Wireless Siren, the Trip with Panel Bell option should be selected in the Output
Setup programming for the siren.
Bell Cutoff Time
Enter the maximum time from 1 to 15 minutes that a wireless output remains on. If the
output is manually silenced or the system is disarmed, the cutoff time is reset. Default is
5
.
Automatic Bell Test
When YES is selected, the 1135INT wireless siren is turned on for two seconds when all
areas in the system are armed. The Bell Test only occurs when the areas are armed from
a keypad. Arming performed from an Arming zone or remotely from Remote Link™ does
not activate the Bell Test.
Closing Wait operation
When Bell Test is set to YES, the closing wait function also operates. Closing Wait
provides a delay time before a monitored system arms until the panel receives an
acknowledgment of the closing report from the central station receiver. During the
delay, the keypad displays ONE MOMENT . . . Once the closing is acknowledged, the
keypad buzzes for one second and then displays the ALL SYSTEM ON message. If
communication fails, the message LOCAL ALARM ONLY appears.
Bell Output
Enter the output number (51-54, 61-64) when it is necessary to follow the on and off
condition of the bell action. Enter 0 (zero) to disable.
When BELL ACTION below is set to T for Temporal Code 3, this Bell Output action will
be Pulse for wireless outputs 51-54 and 61-64.
Bell Action
This defines the type of Bell Action from zone alarms that will occur. Trouble conditions
do not activate Bell Action. There are eight zone types you can
program individually for Bell Output. To provide a steady Bell Output, enter S.
For a pulsed output, enter P. For a Temporal Code 3 output, enter T, enter 4 for a
Temporal Code 4 output, and for no bell action, enter N.
Fire
Defines Bell Action for Fire Type Zones. The default is set at
T
.
Burglary
Defines Bell Action for Burglary Type Zones. The default is set at
S
.
Supervisory
Defines Bell Action for Supervisory Type Zones. The default is set at
N
.
Panic
Defines Bell Action for Panic Type Zones. The default is set at
N
.
Emergency
Defines Bell Action for Emergency Type Zones. The default is set at
N
.
Auxiliary 1
Defines Bell Action for Auxiliary 1 Type Zones. The default is set at
N
.
BELL OPTIONS
BELL CUTOFF:
5
BELL TST
NO
YES
BELL OUTPUT: 0
BELL ACTION . . . . .
FIRE TYPE:
T
BURGLARY TYPE:
S
SUPRVSRY TYPE:
N
PANIC TYPE:
N
EMERGNCY TYPE:
N
AUXLRY 1 TYPE:
N