XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
35
DMP Wireless
For wireless key fob programming see the 1144INT Series Key Fob section.
All wireless programming is stored in the XTLplusINT panel. Each time the panel powers up, when the programmer
STOP routine is selected or the panel is reset, the wireless receiver memory refresh could take up to 45 seconds to
complete depending on the number of wireless zones programmed and the Red LED remains on during this time.
Normal wireless receiver operation is inhibited during the memory refresh period.
Serial Number Entry
Enter the eight digit serial number, including leading zeros, found on the wireless device.
Contact
This option displays if the serial number entered is for an 1103INT Universal Transmitter.
Press any top row key to select the contact.
This option displays when programming an 1103INT Universal Transmitter. Select INT to
use the internal reed switch contacts. Select EXT to connect an external device to the
1103INT terminal block. Default is
INTERNAL
.
By allowing both of the transmitter contacts (INT and EXT) to be used at the same time,
two zones may be programmed from one transmitter. When using multiple contacts, you
must use consecutive zone numbers.
Supervision Time
Press any top row key to select the supervision time required for the wireless zone. Press
CMD to accept the default time.
Select the required number of minutes. The transmitter must check in at least once
during this time or a missing condition is indicated for that zone. 1100INT Series
transmitters automatically checkin based on the supervision time selected for the
wireless zone, no additional programming is needed. If two zones share the same
transmitter, the last programmed supervision time is stored as the supervision time for
both zones. Zero (0) indicates an unsupervised transmitter.
When the panel is reset the supervision timer restarts for all wireless zones.
LED Operation
This only displays when programming a panic or pendant transmitter. Select YES to
turn a panic or pendant LED on during normal operation. Select NO to turn the LED
off during normal operation. The LED always operates on all transmitters when the
transmitter case is open and the tamper is faulted. Default is
YES
.
Disarm/Disable
Select YES to disable the Zone Tripped message on 1103INT Universal Transmitters or
1122INT PIRs during the disarmed period. When disarmed, the transmitter or PIR only
sends Supervision, Tamper, and Low Battery messages to extend transmitter battery
life. For transmitters, a Zone Tripped message is sent if the zone remains tripped for
20 seconds. Leaving the panel defaulted to NO causes the panel to always send Zone
Tripped messages in addition to Supervision, Tamper, and Low Battery.
Wireless PIR Pulse Count
This option displays for 1122INT Wireless PIRs. Select the number of infrared pulse
counts (2 or 4) the PIR will use before sending a short message. The first infrared pulse
starts a timer and count. If no additional infrared pulses occur in 25 seconds, the timer
and count are reset. Default is
4
.
Wireless PIR Sensitivity
This option displays for 1122INT Wireless PIRs. Select the sensitivity setting for the
PIR. Selecting LOW sets the PIR to operate at 75% sensitivity for installations in harsh
environments. Selecting HIGH sets the PIR to maximum sensitivity. Default is
LOW
.
TRANSMITTER
SERIAL#: XXXXXXXX
TRANSMITTER
CONTACT: XXXXXXXX
TRANSMTR CONTACT
INT
EXT
TRANSMITTER
SUPRVSN TIME: 240
SELECT MINUTES:
0 3 60
240
LED OPERATION
NO
YES
DISARM DISABLE
NO
YES
WIRELESS PIR
PULSE COUNT: 4
WIRELESS PIR
SENSITIVITY: LOW