
XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
29
OUTPUT OPTIONS
Output Options
This section allows you to program output options. Select from the following output
numbers:
• 51 to 54
• 61 to 64
• F01 to F20 (To Activate Z-Wave Favorites)
Communication Failure Output
This output/Favorite turns on when the panel fails to communicate with the receiver
after three communication attempts. Enter 0 (zero) to disable this output.
To turn off the Communication Failure Output, disarm the panel or turn the output off
using the User Menu Outputs On/Off function.
Fire Alarm Output
This output turns on any time a fire type zone is placed in alarm. The output turns off
using the Sensor Reset option when no additional fire type zones are in alarm. Enter 0
(zero) to disable this output.
Fire Trouble Output
This output/Favorite turns on any time a fire type zone is placed in trouble or when a
supervisory type zone is placed in alarm or trouble. The output turns off when all fire
and supervisory type zones restore to normal. Enter 0 (zero) to disable.
Ambush Output
This output/Favorite turns on any time an Ambush code is entered at a keypad.
The output turns off using the Sensor Reset option. Enter 0 (zero) to disable this output.
Begin Exit Output
This output/Favorite turns on any time an exit delay time starts. The output turns off
when the system arms or when the arming has been stopped. Enter 0 (zero) to disable.
End Exit Output
This output/Favorite turns on any time an exit delay time ends. The output turns off
when the system disarms. Enter 0 (zero) to disable.
Ready Output
This output/Favorite turns on whenever all disarmed zones are in a normal state. The
output turns off when any disarmed zone is in a bad state. Enter 0 (zero) to disable.
Armed Output
The entered output turns on any time the system is armed. The keypad display is
dependent on the system’s arming type.
For Home/Away systems, only the HOME and AWAY screens display. If a Bedroom
area is programmed into the panel, the SLEEP screen also displays. For All/Perimeter
systems, the ALL and PERIM screens display. For Area systems, the OUT screen displays.
All options are defaulted to 0 (zero). The output turns off when the system completely
disarms. Enter 0 (zero) to disable this output.
Disarmed Output
This output/Favorite turns on when all areas of the panel are disarmed. The output turns
off when an area is armed.
OUTPUT OPTIONS
COM FAIL OUT: 0
FIRE ALR OUT: 0
FIRE TRB OUT: 0
AMBUSH OUT: 0
BEG EXIT OUT: 0
END EXIT OUT: 0
READY OUT: 0
ARMED HOME:
0
ARMED SLEEP:
0
ARMED ALL:
0
ARMED PERIM:
0
ARMED AWAY:
0
ARMED OUT:
0
DISARMED OUT: 0