Digital Monitoring Products
XTLplus International Series Installation and Programming Guide
26
Trouble Audible Annunciation
Press any top row key to select the keypad buzzer annunciation method for wireless low
battery and missing messages.
Select ANY to enable annunciation anytime.
Select DAY to enable annunciation except during sleeping hours (9 PM to 9 AM).
Select MIN (minimum) to annunciate only Fire and CO zones during daytime hours (9
AM to 9 PM). Default is
DAY
.
Enable Keypad Panic Keys
This option allows the two-button panic key operation selected at a keypad to send the
Panic, Emergency, or Fire message to the central station receiver. Select YES to enable
the two-button panic operation. To disable the two-button panic operation, select NO.
Default is
YES
.
Wireless Encryption
Encryption allows the panel to communicate with encrypted 1100INT Series wireless
devices that are v700 and higher. Select ALL to to allow encryption for all the wireless
devices programmed into the panel. Select BOTH to allow both encrypted and non-
encrypted wireless devices to be programmed into the panel. Select NONE to don’t
allow encryption for wireless devices programmed into the panel. The default is
NONE
.
Enter Passphrase
ENTER PASSPHRASE displays if you select ALL or BOTH for wireless encryption. In
order for the panel to support encrypted 1100INT Series wireless devices, a passphrase
must be entered. The passphrase must be an 8-digit hexadecimal number which
determines the system’s encryption key.
Occupied Premises
Select YES to allow the panel to automatically disarm the interior area(s) when arming
all areas and a perimeter zone is not tripped during the exit delay.
This False Alarm Reduction feature keeps a user from arming the entire system when
they do not exit and remain in the premises. Select NO to not automatically disarm
interior area(s). Default is NO.
Use False Alarm Question
Select YES to display IS THIS A FALSE ALARM? NO YES at the keypad in place of
CANCEL VERIFY when a burglar alarm occurs. Select NO to display CANCEL VERIFY
for burglar alarms. This operates for ALL/PERIM and HOME/SLEEP/AWAY arming
systems. Default is
YES
.
Weather Postal Code
This option allows local weather updates to display on the keypad. Enter the postal
code of the user at this option. Press CMD and enter the two-letter country code (ISO2).
When no number is entered weather conditions are not displayed. Default is -.
TRBL AUDIBLE: DAY
KEYPAD PANIC KEYS
ENABLED: NO
YES
1100 ENCRYPTION
ALL BOTH
NONE
1100 PASSPHRASE
********
OCCUPIED
PREMISES: NO
YES
USE FALSE ALARM
QUESTION NO
YES
ENTER WEATHER
ZIP CODE: