COMMUNICATION
Communication
The Communication section allows you to configure the communication settings for the
XTLplus INT panel.
Account Number
Enter the account num ber sent to the receiver.
DD, NET, CELL - The range of account numbers for Digital Dialer, Network, and Cell is 1
to 65535. For account numbers of four digits or less, you do not have to enter leading
zeros. The panel automatically right justifies the account number.
CID - The account number range for this format is 1 - 9999.
Transmission Delay
Enter the number of seconds (15 to 45 seconds) the panel waits before sending burglary
alarm reports to the receiver. The wireless siren and relay outputs are not delayed during
this period. Enter 0 (zero) to disable this function. The default is
30
.
Communication Type
This specifies the communication method the panel uses to contact the receiver. Press
any select area to display the following communication options:
• WIFI
: Network communication to DMP Model SCS-1R or SCS-VR Receivers.
• CEL
: This option allows communication over the cellular network using the 265LTE-
INT Series Cellular Communicator to DMP Model SCS-1R or SCS-VR Receivers.
• NONE:
For local systems. Selecting this ends communication programming.
If automatic cellular activation is unsuccessful, cellular communication must be activated
using the Activate Cell option provided in Diagnostics Function located in the Appendix.
Backup Cellular
Backup Cellular option is available if COMM TYPE is set for WIFI. The Backup Cellular
tries to send the message after the main communication fails for 60 seconds on WIFI. If
the backup cellular fails then the message is discarded.
Test Time
Press
CMD
to enter the Test Time. Enter the time of day the panel sends the test report
to the SCS-1R Receiver. Use entries between 12:00 to 11:59 and then choose AM or PM.
Test Days
Enter how often the panel test report is sent to the receiver. Enter from 1 to 60 days.
Enter zero to disable the test report. Default is
1 (one) day
. This option only displays if a
test time is entered.
Check-In Minutes
Check-in reports are a method of supervising the panel for communication with the
receiver. Enter the number of minutes between check-in reports. Select from 0 or 3-240
minutes. Entering 0 (zero) disables the check-in option. Default is
0
. If the Cell Check-In
option is used, additional cell charges may apply.
Fail Time
Fail Time allows the receiver to miss a defined number of check-in minutes before
logging that the panel is missing. For example, if CHECKIN minutes is 20 and Fail TIME
minutes is 30, the receiver only indicates a Panel Not Responding after 30 minutes. The
Fail TIME must be equal to or greater than the CHECKIN minutes: If the CHECKIN is 20
minutes, the FAIL TIME must be 20 or more. The maximum FAIL TIME is 240 minutes.
The default FAIL TIME is
240 minutes
.
COMMUNICATION
ACCOUNT NO:
XMIT DELAY:
30
COMM TYPE: CELL
WIFI CEL NONE
BACKUP CELL
NO
YES
TEST TIME
00:00 AM
TEST DAYS:
1
CHECKIN:
0
FAIL TIME:
240