Late To Open
Enter 1-240 as the number of minutes to elapse that the system may remain armed after
the opening time of a schedule without sending a Late To Open message. If the system
continues to be armed after the Late to Open minutes expire, a Late To Open message is
sent to the central station. Default is
0
, which disables the Late To Open option.
Early To Close
Enter 1-240 as the number of minutes that the system can be armed prior to the
scheduled closing time. If the system is armed prior to the Early to Close minutes, an
Early To Close message is sent to the central station. Default is
0
, which disables the
Early to Close option.
Entry Check-in Protection
If YES is selected, this enables the panel to send a Serial 1 check-in message when an
Entry Delay begins. The fail time included in this message is the programmed Entry
Delay (rounded up to the nearest minute) plus one minute.
When the System is Disarmed, (either before or after going into Alarm, regardless of
Transmit Delay) another check-in message will be sent. The fail time for this check-
in message is 0 if regular check-ins are not programmed and is the normal fail time if
check-ins are programmed. During the time frame between the beginning of the Entry
Delay and the following check-in message, regular check-in messages are suspended.
The default is
YES
.
LATE TO OPEN
MINUTES:
0
EARLY TO CLOSE
MINUTES:
0
ENTRY CHECKIN
NO
YES