Digital Monitoring Products
XTLplus International Series Installation and Programming Guide
10
Installing a lockout code
1. After entering the Programmer menu, the keypad displays PROGRAMMER. Press
CMD
until SET LOCKOUT
CODE is displayed (after STOP).
2. Press any select key. At the ENTER CODE: - display, enter a 1- to 5-digit programmer lockout code. Press
CMD
.
3. The display shows ENTER AGAIN. Enter the same lockout code again and press
CMD
. The display shows
CODE CHANGED. The new code number must now be entered before the Programmer menu can be
accessed.
The lockout code should be written down and kept in a secure place with access limited to authorized persons only.
Lost Lockout Code requires factory reset: If you lose or forget the lockout code, the panel must be sent back to the
factory to be reset. There is no field option for gaining access to the panel without a valid lockout code.
Reset Timeout
The XTLplusINT has a feature that requires you to enter the Programmer within 30 minutes of resetting the panel.
After 30 minutes, if you attempt to program by entering the 665 (PRO) code, the keypad displays: RESET PANEL. You
must reset the panel and enter the program code within the next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30 minutes, the panel
terminates programming. All data entered up to that point is saved in the panel’s memory.
To exit the panel’s Programmer you must use the Stop function. The STOP option is the second to the last option in
programming. The programming session is then terminated and the keypad returns to the Status List.
INITIALIZATION
Initialization
This function allows you to clear selected parts of the panel program back to the factory
defaults.
Clear All Codes
NO
leaves existing codes intact.
YES
clears the user code and user profile memory and assigns user code number 99 to
the highest user number
.
Clear All Schedules
NO
leaves existing schedules intact.
YES
clears all shift and output schedules.
Clear Display Events Memory
NO
leaves existing event memory intact.
YES
clears the events memory.
Clear Zone Information
NO
leaves existing zone information intact.
YES
clears the zone information for all zones.
Clear Communication Options
NO
leaves existing communication options intact.
YES
reset communication and remote options programming to factory defaults.
Clear Wi-Fi
NO
leaves existing Wi-Fi programming intact.
YES
reset Wi-Fi programming to factory defaults.
Set to Factory Defaults
NO
leaves existing panel programming intact.
YES
sets the panel’s programming back to factory default selections. Selecting
YES
does not clear the panel’s event memory, zones, user code information, or schedules.
INITIALIZATION
INITIALIZATION
CODES? NO YES
SCHEDS? NO YES
EVENTS? NO YES
ZONES? NO YES
COM/RMT? NO YES
WIFI? NO YES
DEFAULTS NO YES