XTLplus International Series Installation and Programming Guide
Digital Monitoring Products
39
To enter an Output Number, press any select area followed by the output number 51-54,
61-64, or F1-F20. Press
CMD
.
Output Action
Entering an Output Number displays this option that allows you to assign an output
action. A description of the available output actions is given below:
STEADY - The output is turned on and remains on until the area is disarmed, an output
cutoff time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second off until the area is
disarmed, an output cutoff time expires, or the output is reset from the keypad User
Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off normal, or
bad condition. When the zone restores, the output is turned off.
After you have selected the Message To Transmit, the display prompts you for the same
three selections for Disarmed Short, Armed Open, and Armed Short conditions. If the
zone is a 24-hour type, only the Armed Open and Armed Short conditions are displayed.
When you have programmed all of the zone conditions, the Swinger Bypass selection is
then dis played.
Swinger Bypass
Selecting YES allows the zone to be swinger bypassed by the panel according to the
programming in Swinger Bypass Trips and Reset Swinger Bypass. The Bypassed zone
displays in the keypad Status List. Selecting NO disables swinger bypassing for this
zone.
How it works
If within one hour, a zone trips the total number of times as specified in Swinger Bypass
Trips, the panel bypasses it until the following conditions occur; the area in which the
zone is assigned is disarmed, the zone is manually reset through the Bypass Zones
keypad User Menu function, the zone remains normal for one hour and the Reset
Swinger Bypass is YES.
If the zone trips fewer than the specified times within one hour of the first trip, the
bypass trip counter returns to 0 (zero) and the process must be repeated.
A report of the swinger bypass is sent to the receiver if Bypass Reports is YES.
Prewarn Address
Option is only shown for an Exit zone.
At the start of the entry delay, all keypad addresses dis play ENTER CODE:-. If you want
the prewarn to sound at all addresses, leave the default as shown.
To delete an address, press the matching number on the keypad. To disable prewarning
at all keypads, press a top row key to clear the addresses shown. Press
CMD
when the
address selection is com plete.
The prewarn tone stops at the keypad when the first digit of a user code is entered. If,
within five seconds, a valid user code is not entered or an invalid user code is entered,
the prewarn tone begins sounding again. Fifteen seconds must elapse before entering a
digit silences the prewarn tone again.
Chime
Option is only shown for Night, Exit, and Instant zones. Select either NONE, DB
(doorbell), DESC (descend), or ASC (ascend) to assign that tone to a zone. Default is
DOORBELL
for Exit zones and NONE for Night zones.
Entry Delay
Option is only shown for an Exit zone. Select the entry delay timer for this
zone. Entry delay timers 1 and 2 are programmed in Entry Delay in the System Options
menu.
OUTPUT: NONE
STD PLS MOM FOLW
SWGR BYP NO
YES
PREWARN KEYPADS:
CHIME: DOORBELL
ENTRY DELAY: 1