Resetting FastPort to Factory Defaults
A.1 Resetting by Toggling the DIP Switches
Note:
This will also reset the IP Address back to 0.0.0.0.
1. Place all the front panel switches down.
Note:
Unplug then plug back in the power supply.
2. Wait at least 4 seconds.
3. Toggle switches D4 up and down quickly at least 10 times.
4. Reset switches back into normal printing mode.
5. Power cycle the unit.
A.2 Resetting by Console Option
1. Establish a serial, telnet, or NetBIOS console monitor to obtain the
Options menu (or Available Command menu)
2. In the Options menu, press [Z] (option Z) to reset the unit.
Note:
An option to reset the IP address appears. Select to do so.
3. After NVRAM write is done, press [R] to end the console session and
reset FastPort.
A.3 Hardware Features
• The MIL-3000FTX board, with Ethernet controller, serial, and parallel
port interfaces
• CPU: An 80186 processor, with a 16 MHz clock
• Memory: 256K RAM
• Flash: Flash device is 29F040. It is a 4 Mbps EEPROM and arranged in 2
×
256k
×
8 format.
• MAC chipsets: Ethernet controller is 10/100 Mbps, with its own
memory management
• 10/100BASE-TX, RJ-45 (unshielded twisted pair) connector