Delta SCARA Robot System User Manual
SCARA CE Series
78
The installation position of the first arm limit point of DRS70L6 series is as shown in Figure 5.13 below.
Figure5. 13
The installation position of the first arm limit point of DRS70L6 series
Table 5.11 below is the first arm point screw and locking torque for DRS70L6 series installation.
T
able5. 11
DRS70L6 series first arm active hardware point locking torque
Name
Screw torque value
Remark
Tool
#4 hex wrench
5.7 to 6 N-m
M5x20 hex socket screws
The installation position of the second arm active point and angle (101°, 121°, 141°) of DRS 6kg series
are as shown in Figure 5.14 below.
Figure5. 14
DRS 6kg series installation position of the second arm active point and angle
M5x20 hex socket screws (screws used to keep fixtures in place)
M5X20 hex socket screws (full-stroke screws used to keep fixtures in place)
M5X20 hex socket screws
(screws used to keep fixtures in place)
J1=49° (active point)
J1=62.5° (active point)
J1=62.5° (active point)
J1=49° (active point)
M8X12 hex socket
J1=133°M8x20 hex socket screw (limit point)
J2=121°
J2=101°
J2=141°
J2=141°
J2=101
J2=121°
Содержание DRS40L3SOADF003
Страница 1: ...Delta SCARA Robot System User Manual SCARA CE Series 1 ...
Страница 59: ...Delta SCARA Robot System User Manual SCARA CE Series 59 ...
Страница 64: ...Delta SCARA Robot System User Manual SCARA CE Series 64 Figure4 5 DRS70L series dimensions figure ...
Страница 113: ...Delta SCARA Robot System User Manual SCARA CE Series 113 ...
Страница 115: ...Delta SCARA Robot System User Manual SCARA CE Series 115 ...
Страница 129: ...Delta SCARA Robot System User Manual SCARA CE Series 129 ...