The output signal DO includes a total of 8 points of output from Pin7~Pin22; the output method can be
NPN or PNP.
Customers can freely choose whether the output voltage signal will be controller voltage output or
upper controller voltage output.
When the selected output voltage signal is the controller voltage output
The NPN wiring method is as shown in Figure 7.25 below:
Figure7. 25 System DO controller voltage output NPN wiring
The PNP wiring method is as shown in Figure 7.26 below:
Figure7. 26 System DO controller voltage output PNP wiring
Mixed NPN and PNP wiring method is as shown in Figure 7.27 below:
In the figure below, PNP output wiring is used for the lamp and NPN output wiring is used for the relay.
Figure7. 27 System DO controller voltage mixed output wiring