Delta SCARA Robot System User Manual
SCARA CE Series
173
8.7 How to save injured workers
If workers were accidentally hit and injured, or got caught by the robot, please save them using the
following steps.
1.
Press the emergency stop button to cut off the power sent to the robot from the controller, as
shown in Figure 8.41.
You can also turn off the controller or the master power switch installed by the final system
integrator.
Figure8. 41 Press the emergency stop button
2.
Since the J1 and J2 axes of the DRS series robots do not have brakes, the robot can be pushed to
the left or right as shown in Figure 8.42.
Figure8. 42 Push robot figure
DRS40/50/60/70L series
DRS60H series