Delta SCARA Robot System User Manual
SCARA CE Series
114
When the selected output voltage signal is the upper controller voltage output
The NPN wiring method is as shown in Figure 7.19 below:
Figure7. 19 User DO upper controller voltage output NPN wiring
The PNP wiring method is as shown in Figure 7.20 below:
Figure7. 20 User DO upper controller voltage output PNP wiring
Upper controller mixed NPN and PNP wiring method is as shown in the figure below:
In Figure 7.21 below, PNP output wiring is used for the lamp and NPN output wiring is used for the
relay.
Figure7. 21 User DO upper controller voltage mixed output wiring
Note:
1.
Each DO output point can supply 40mA at most. To activate heavy current load, please execute
through the relay.
2.
Do not connect AC power to the DO output point; such wiring methods will damage the controller.