Delta SCARA Robot System User Manual
SCARA CE Series
119
When the selected output voltage signal is the upper controller voltage output.
The NPN wiring method is as shown in Figure 7.28 below:
Figure7. 28 System DO upper controller voltage output NPN wiring
The PNP wiring method is as shown in Figure 7.29 below:
Figure7. 29 System DO upper controller voltage output PNP wiring
Upper controller mixed NPN and PNP wiring method is as shown in Figure 7.30 below:
In the figure below, PNP output wiring is used for the lamp and NPN output wiring is used for the relay.
Figure7. 30 System DO upper controller voltage mixed output wiring
Note:
1.
Each DO output point can supply 40mA at most. To activate heavy current load, please execute
through the relay.
2.
Do not connect AC power to the DO output point; such wiring methods will damage the controller.
Содержание DRS40L3SOADF003
Страница 1: ...Delta SCARA Robot System User Manual SCARA CE Series 1 ...
Страница 59: ...Delta SCARA Robot System User Manual SCARA CE Series 59 ...
Страница 64: ...Delta SCARA Robot System User Manual SCARA CE Series 64 Figure4 5 DRS70L series dimensions figure ...
Страница 113: ...Delta SCARA Robot System User Manual SCARA CE Series 113 ...
Страница 115: ...Delta SCARA Robot System User Manual SCARA CE Series 115 ...
Страница 129: ...Delta SCARA Robot System User Manual SCARA CE Series 129 ...