Axis category:
E?001 over-current
Cause
1. Driver output short-circuited.
2. Motor connection error.
3. IGBT abnormal.
Inspection and
disposal
method
1. Check whether the wiring between the motor and driver has short-circuited; if
short-circuited, please eliminate the short-circuit status and prevent the wiring
from being exposed.
2. Please refer to the wiring order in the manual and check the wiring order for
connecting the motor to the driver, then re-wire it again. Please send this product
back to the dealer or original manufacturer for repairs if problems still exist.
Solution
Abnormality warning reset.
E?002 over-voltage
Cause
1. Main circuit input voltage too high.
2. Driver hardware malfunction.
Inspection and
disposal
method
1. Check whether the input voltage of the main circuit is within the rated voltage
value; if not, please use the correct voltage component or connect a stabilizer to
convert the voltage to within the rated range.
2. Check whether the input voltage of the main circuit is within the rated voltage
range; if this error still occurs, please send the driver back to the dealer or original
manufacturer for repairs.
Solution
Abnormality warning reset.
E?003 under-voltage
Cause
1. Main circuit input voltage too low.
2. Main circuit has no input voltage source.
3. Power input error.
Inspection and
disposal
method
1. Use an ammeter to measure the voltage to see whether the voltage of the main
circuit is normal.
2. Please refer to the wiring order in the manual to check whether the wiring of the
main circuit input voltage is normal; if there is wiring error, please re-wire.
3. Check whether the power system complies with the specification definition; please
use the correct voltage component or connect a stabilizer to convert the voltage
to within the rated range.
Solution
Voltage recovery and clear.
E?004 motor match error
Cause
1. Encoder loose.
2. Motor match error.
Inspection and
disposal
method
Please return it to the dealer or original manufacturer for repairs.
Solution
Reconnect the power and clear.
Содержание DRS40L3SOADF003
Страница 1: ...Delta SCARA Robot System User Manual SCARA CE Series 1 ...
Страница 59: ...Delta SCARA Robot System User Manual SCARA CE Series 59 ...
Страница 64: ...Delta SCARA Robot System User Manual SCARA CE Series 64 Figure4 5 DRS70L series dimensions figure ...
Страница 113: ...Delta SCARA Robot System User Manual SCARA CE Series 113 ...
Страница 115: ...Delta SCARA Robot System User Manual SCARA CE Series 115 ...
Страница 129: ...Delta SCARA Robot System User Manual SCARA CE Series 129 ...