Delta SCARA Robot System User Manual
SCARA CE Series
41
3.2 Robot safety protection construction and installation
3.2.1 Emergency stop device installation
Must be dual-channel NC contact mechanical type emergency stop device.
When the emergency stop button is used:
1.
It must be a red type and has yellow background (the area of the yellow background must be
greater than the red), as shown in Figure 3.1.
Figure3. 1 Emergency stop button
2.
Equipped with a manual re-set function, as shown in Figure 3.2.
Figure3. 2 Emergency stop switch re-set method
3.
Equipped with a disconnect function so that when the contacts are fused, the force used to press
the button can be used to disconnect the fused contacts. This function symbol is as shown in
Figure 3.3
Figure3. 3 Emergency stop safety disconnect symbol
4.
Please install multiple emergency stop devices according to the actual overall system, and take
into consideration not to make the installation distance between each emergency stop too far in
Rotation re-set
Drawing re-set