Anti-jerk
Base Anti-jerk algorithm
Anti-jerk on-the-top
For dampen STW speed
fluctuations
Flow command1
Flow command
Flow command
Anti-jerk on-the-top
LPF
Average
Crossover
EEPROM parameters
STW Anti-jerk filter Cut-off
frequency (P3582)
STW Anti-jerk Cross-over start (P3578)
STW Anti-jerk Cross-over stop (P3580)
Flow command
Flow command1
Average flow command
Flow command
LPF flow command
Crossover
100%
0%
P3578
P3580
Factor LPF flov command
Factor flow command
|average flow command|
Out = Factor LPF flow command x LPF flow c Factor flow command x flow command
Figure 44
Referring to the Figure below, the ‘crossover/mixing factor’ in percentage is calculated and is applied on ‘
Filtered flow
set-point
’ (see 10.6.1) to calculate the final ‘
flow set-point
’ of Anti-jerk algorithm.
Parameters P3578 and P3580 are used to calculate the percentage crossover to be applied on the ‘
filtered flow set-point
’(see
10.6.1) to calculate the final ‘
flow set-point
’ with anti-jerk functionality.
The ‘Crossover/mixing factor’ is defined by the piece-wise linear characteristics based on following points in Figure 5.
The absolute value of average flow set-point is calculated from ‘
Modified Flow Set-point
’(see 10.6.1) and ‘
Filtered Flow
Set-point
’ (see 10.6.1) in IR.
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...