© Danfoss | August 2018
AQ00000211 |
173
ENGINEERING TOMORROW
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
WAS max left position
(CAN)
P3185
U16
mVolts
Wheel angle sensor voltage output for leftmost position over CAN
OEM, Dealer
0
5000
500
WAS max right position
(CAN)
P3187
U16
mVolts
Wheel angle sensor voltage output for rightmost position over CAN
OEM, Dealer
0
5000
4500
WAS neutral position
(CAN)
P3189
U16
mVolts
Wheel angle sensor voltage output for neutral position over CAN
OEM, Dealer
0
5000
2500
Automatically adjusted
cylinder stroke volume
(CAN WAS)
P3191
U16
ccm
Automatic adjusted cylinder stroke volume, for using CAN WAS, found
during WAS auto-calibration
OEM, Dealer
100
65535
65535
Automatically adjusted
maximum steer angle to
left side (CAN WAS)
P3193
U16
Deg
Automatic adjusted maximum steer angle to left side, for using CAN WAS,
found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Automatically adjusted
maximum steer angle to
right side (CAN WAS)
P3195
U16
Deg
Automatic adjusted maximum steer angle to right side, for using CAN
WAS, found during WAS auto-calibration
OEM, Dealer
0
65535
65535
Table 84
•
Calculate the sector CRC as CRC-16-CCITT(P3185…P3196) and store (word) at the CRC/Checksum address
(P3203). For example of how to calculate sector CRC, please see paragraph 17.5.2.
•
Furthermore, populate a temporary data sector for “Production/Calibration Flag”. Update the CAN based WAS
calibration counters. Increment P3775 from 0 to 1 and increment bit-wise inverted P3776 from 255 to 254 for the
displayed below,
Production/Calibration Flag
Name
A
ddr
es
s
D
at
a t
yp
e
U
ni
t
Description of parameter
U
se
r
Range
D
a
nf
o
ss
de
fa
ul
t
val
u
e
S
a
fet
y
cri
ti
ca
l
p
a
ra
m
et
ers
‘
S
’
Mi
n
.
M
ax.
Calibration counter - Spool calibration
P3771
U8
-
Calibration counter - Spool calibration
OEM
0
255
0
Bit inverted value for "Calibration counter - Spool
calibration"
P3772
U8
-
Bit inverted value for "Calibration counter - Spool
calibration"
OEM
0
255
255
Calibration counter - Analogue WAS calibration
P3773
U8
-
Calibration counter - Analogue WAS
OEM
0
255
0
Bit inverted value for "Calibration counter - Analogue
WAS calibration"
P3774
U8
-
Bit inverted value for "Calibration counter - Analogue
WAS"
OEM
0
255
255
Calibration counter - CAN WAS calibration
P3775
U8
-
Calibration counter - CAN WAS
OEM
0
255
0
Bit inverted value for "Calibration counter - CAN
WAS calibration"
P3776
U8
-
Bit inverted value for "Calibration counter - CAN WAS"
OEM
0
255
255
Calibration counter - Analogue joystick
P3777
U8
-
Analogue sensor based Joystick calibration counter
OEM
0
255
0
Bit inverted value for "Calibration counter - Analogue
joystick"
P3778
U8
-
Bit inverted value for Analogue sensor based Joystick
calibration counter
OEM
0
255
255
Table 85
•
Calculate the sector CRC as CRC-16-CCITT (P3771…P3778) and store (word) at the CRC/Checksum address
(P3789). For example of how to calculate sector CRC, please see paragraph 17.5.2
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...