172 | © Danfoss | August 2018
AQ00000211
ENGINEERING TOMORROW
•
Calculate the sector CRC as CRC-16-CCITT (P3771…P3778) and store (word) at the CRC/Checksum address
(P3789). For example of how to calculate sector CRC, please see paragraph 17.5.2.
Write parameters to PVED-CLS’ EEPROM
•
Put PVED-CLS into “bootloader mode”
•
For MAIN-controller:
o
Write data sector “Analogue Sensor Calibration data”
o
Read back data (verification)
o
Acknowledge data correctness
o
To sign acknowledge, calculate signature CRC and write it at the CRC/signature address (P48)
o
Write data sector “Production/Calibration Flag”
•
For SAFETY-controller:
o
Write data sector “Analogue Sensor Calibration data”
o
Read back data (verification)
o
Acknowledge data correctness
o
To sign acknowledge, calculate signature CRC and write it at the CRC/signature address (P48)
•
Calculate the sector CRC as CRC-16-CCITT (P3771…P3778) and store (word) at the CRC/Checksum address
(P3789). For example of how to calculate sector CRC, please see paragraph 17.5.2.
17.6.3
Calibrating CAN-based wheel angle sensor
The following description explains how to manually calibrate your CAN-based wheel angle sensor. The procedure
consists of three main steps:
1.
Read sensor values
2.
Data sector preparation
3.
Write parameters to PVED-CLS’ EEPROM
The following is a more detailed description of each main step:
Read sensor values
•
Put PVED-CLS into “WAS calibration service mode”
•
Turn wheels into far left angle position
o
Read primary wheel angle via CAN message and temporarily store the value
o
Read secondary wheel angle via CAN message and temporarily store the value
•
Turn wheels into neutral/straight position
o
Read primary wheel angle via CAN message and temporarily store the value
o
Read secondary wheel angle via CAN message and temporarily store the value
•
Turn wheels into far right angle position
o
Read primary wheel angle via CAN message and temporarily store the value
o
Read secondary wheel angle via CAN message and temporarily store the value
Data sector preparation
•
For MAIN- and SAFETY-controller, populate a temporary data sector for “CAN WAS Calibration data”. Use
the temporarily stored values from “main step 1” for the displayed below,
CAN WAS Calibration data
Содержание PVED-CLS
Страница 6: ...6 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...
Страница 71: ... Danfoss August 2018 AQ00000211 71 ENGINEERING TOMORROW Figure 29 ...
Страница 127: ... Danfoss August 2018 AQ00000211 127 ENGINEERING TOMORROW ...
Страница 147: ... Danfoss August 2018 AQ00000211 147 ENGINEERING TOMORROW ...
Страница 182: ...182 Danfoss August 2018 AQ00000211 ENGINEERING TOMORROW ...