The DELAY time sets the amount of time the control requires the program select
inputs (BCD or Binary) to remain stable before the control will recognize and run a
program.The minimum time is 1 ms.If program select inputs are not stable for a
time equal to or greater than the specified delay, the program will not be executed.
Use numeric keys to enter a value in ms.
EDIT
SETUP PROG ECHO
Echo Enable [EC]
Default:ENABLED
- - - - RS232 Echo - - - -
á
ENABLED
â
RS232 RS-232C Configuration
If you plan to use the serial communications port on
your Smart Drive, you can use your keypad to turn the auto-echo on and off and set
the unit’s daisy chain address.The baud rate of 9600 is fixed on the Smart Drive.
Fixed RS-232 parameters:
• Baud rate:9600
• Data bits: 8
• Stop bits: 1
• Parity:none
This option is used to enable or disable the RS-232C echo.If the ECHO is disabled,
characters received by the control’s serial port will not be re-transmitted.ECHO
must be enabled in daisy chaining applications.
Use the
áâ
keys to enable or disable the ECHO.
This option is used to set the unit address.Each unit in an RS-232C serial daisy
chain of multiple units must have a unique Unit Address.Refer to the section on
daisy chain operation in the
RS-232 Operation
chapter for more information on
this type of application.
Use the numeric k eys to enter the unit address.
MISC Miscellaneous Configuration Parameters
The following miscellaneous set-up parameters
include auto-formatting of the keypad display, setting
the deceleration rate used with a stop input,or the
ESC key while an axis is moving,and disable/enable
the TEST menus accessible from the RUN function
key.
- -
á
MISC SETUP
â
- -
DISP STOP-RATE TEST
- -
á
MISC SETUP
â
- -
FAULT ENABLE PASWRD
EDIT
SETUP PROG DELAY
Scan Delay [DY]
Default:100 ms
- - - Scan Debounce: - -
DELAY (ms): _
- - - RS232 SETUP - - -
ECHO UNIT #
EDIT
SETUP PROG UNIT#
Unit Number [UN]
Default: 1
Range:(1-99) (Limited to 1-15 in firmware version 1.40 and earlier)
- - - Unit Address - - -
NUMBER: _
Содержание B8961
Страница 111: ...109 Chapter 7 Programming with Serial Communication...
Страница 132: ...B8961 and B8962 User Manual 130...
Страница 136: ...B8961 and B8962 User Manual 134 B8961 and B8962 Hardware Connections...
Страница 137: ...135 Chapter 8 Hardware Reference B8961 and B8962 Input and Output Schematics...
Страница 138: ...B8961 and B8962 User Manual 136 Connecting IDC Limit Switches to the B8961 2...
Страница 156: ...B8961 and B8962 User Manual 154...