Chapter 4 - Configuring Your System
39
Specify the final approach direction of your Go Home (GH) move with this option.
This is the direction used to search for the encoder index mark (Z channel) after
the appropriate home switch edge is found.
1.
Use
ß
and
à
keys to select an axis.
2.
Use
á
and
â
keys to select the final approach direction.
EDIT
SETUP HOME FINAL
Home Final Direction [HF]
Default:POSITIVE
- Axis One Final Dir. -
ß
POSITIVE
à
EDIT
SETUP PROG PWR-UP
Power Up Program [PU]
Range:n = 0 to 199 (0-400 w/ -30k option)
Default: 0
- - Power Up Program -
PROGRAM: 0
PROG Program-Run Configuration
Your
IDeal
™
Programmable Smart Drive is capable
of running any pre-defined program on power-up,
or whenever a valid BCD or binary program combination is read on inputs
configured as BCD or Binary Program Select inputs (usually from a PLC or thumb-
wheel switches).The conditions under which these programs execute are defined
in PROGRAM SETUP.
- PROGRAM SETUP -
PWR-UP SCAN DELAY
This option selects a power-up program.The selected program is executed (run)
when your Smart Drive is powered up or reset.If a value of 0 is entered in this
menu,or if the specified program does not exist,no program is run.
Use the numeric k eys to enter a program number.
The SCAN menu allows you to select which events will cause the control to stop
scanning program-select configured inputs.It is used to enable or disable stop-scan
events.If a given stop-scan event is enabled,the system will stop scanning the
inputs for program numbers when that condition occurs.The Smart Drive must be
reset via a Warm Boot input or by cycling power to start program scanning after an
active Stop Scan event.This option has no effect if the inputs have not been config-
ured as program select inputs (either BCD or Binary).
1.
Each event is represented by one of seven Y/N positions on the bottom display
line.Use
ß
and
à
keys to select a stop-scan condition.The selected event will
be listed to the right of these 7 characters:ESCape,STOP, LIMIT+,LIMIT-,KILL,
FAULT or INTerrupt.
2.
Use
á
and
â
keys to enable (Y) or disa ble (N) the selected event.
EDIT
SETUP PROG SCAN
Scan Conditions [SN]
Default:YYYYYYY
- - -Stop Scan After- - -
ßá
YYYYYYY ESC
âà
Содержание B8961
Страница 111: ...109 Chapter 7 Programming with Serial Communication...
Страница 132: ...B8961 and B8962 User Manual 130...
Страница 136: ...B8961 and B8962 User Manual 134 B8961 and B8962 Hardware Connections...
Страница 137: ...135 Chapter 8 Hardware Reference B8961 and B8962 Input and Output Schematics...
Страница 138: ...B8961 and B8962 User Manual 136 Connecting IDC Limit Switches to the B8961 2...
Страница 156: ...B8961 and B8962 User Manual 154...