B8961 and B8962 User Manual
66
DE
Deceleration
syntax - DEr,r
Units:
sec,rps2 or unit/s2
Range:
unit scaling dependent
Default:
n/a
Sets the deceleration ramp on all negative velocity changes. The deceleration value
will be the same as the acceleration value unless a deceleration is specified.The
value set will be used on subsequent moves unless it is re-specified by
either
an
acceleration (AC) or deceleration (DE) command.
Examples:
AC2 VE12 DA3 GO
Sets acceleration and deceleration to 2.
DE.5VE12 DA6 GO
Accel stays at 2 and decel changes to 0.5.
VE20 DA0 GO
Acceleration and deceleration remain at
2 and 0.5.
AC4 DA2 GO
Both acceleration and deceleration become 4.
DE3 AC1 DI3 GO
AC1 sets
both
the accel and decel to 1.
DI
Distance Incremental
syntax - DI±r, ±r
Units:
selected from the EDIT > SETUP > MECH menu
Range:
unit scaling dependent
Default:
n/a
DI specifies a move distance relative to the current position.Such moves are called
incremental moves,as opposed to the absolute zero reference used in DA.
Incremental moves are typically used in applications where there is no concern for
origin,such as feed-to-length applications.Incremental moves are also often used
inside a loop to shorten a program.Incremental and absolute moves may be mixed
- the control always keeps track of the absolute position.
Example:
AC.1 VE60 DI2 GO DI1 GO DI-4 GO
Move 2 units in the + direction.Move 1 more unit in the positive direction. Move 4
units in the negative direction.The final absolute position is -1.0000.
EA
Enable/Disable Amplifier
syntax - EAi,i
Units:
n/a
Range:
0 (disable),1 (enable),2 (standby)
Default:
n/a
EA sets the state of the amplifier enable signal.The polarity can be changed in EDIT
> SETUP > MISC > ENABLE.
Example:
EA0
Disables the amplifiers on axis one and two.
Содержание B8961
Страница 111: ...109 Chapter 7 Programming with Serial Communication...
Страница 132: ...B8961 and B8962 User Manual 130...
Страница 136: ...B8961 and B8962 User Manual 134 B8961 and B8962 Hardware Connections...
Страница 137: ...135 Chapter 8 Hardware Reference B8961 and B8962 Input and Output Schematics...
Страница 138: ...B8961 and B8962 User Manual 136 Connecting IDC Limit Switches to the B8961 2...
Страница 156: ...B8961 and B8962 User Manual 154...