Chapter 7 - Programming with Serial Communication
117
Serial Setup Commands
These are the commands that the
Application Developer
program uses to configure the
SmartDrive according to the choice made in the SETUP dialog boxes.
Command
Command Description and Application Examples
Syntax
SN
Scan Conditions
<n>SNiiiiii
Conditions stopping input program select line
ii
(BIN/BCD) scanning are represented by: i”
0 = Continue program select scanning,
1 = Stop program select scanning on this condition
Example: SN:0111111 (all input conditions, except
pressing the ESC key stop program select line scanning)
See also: ID
SR
Stop Deceleration Rate
<n>SRr,r
Example: SR100 (100 rps2)
Note: Stop Deceleration Rate units are always in rps2
and are not user selected.
UN
Unit Number
<n>UNi
Example: UN5 (sets unit address to 5)
VU
Velocity Units
<n>VUi,i
Example: VU2 (axis one set to rps)
See also: GR, DU
ESC
Stop
Limit+
Limit-
Kill
Fault
Interrupt
SN
i
i
i
i
i
i
i
0
units/sec (where units is a string defined by the DU command)
1
units/sec (where units is a string defined by the DU command)
2
rps (motor revs/sec)
3
rpm (motor revs/min)
Содержание B8961
Страница 111: ...109 Chapter 7 Programming with Serial Communication...
Страница 132: ...B8961 and B8962 User Manual 130...
Страница 136: ...B8961 and B8962 User Manual 134 B8961 and B8962 Hardware Connections...
Страница 137: ...135 Chapter 8 Hardware Reference B8961 and B8962 Input and Output Schematics...
Страница 138: ...B8961 and B8962 User Manual 136 Connecting IDC Limit Switches to the B8961 2...
Страница 156: ...B8961 and B8962 User Manual 154...