B8961 and B8962 User Manual
128
Serial Supervisory Commands
The following commands control program uploading, downloading, deleting,
execution, etc. All of these commands are fully defined in this section.
Command Command Description and Application Examples
Syntax
EC
RS-232C Echo Enable/Disable
0 = echo Disabled, 1 = echo Enabled.
Example: EC0 (echo off)
The RS-232C Echo must be enabled for daisy chain
operation
<n>ECi
EP
End Program Definition
Denotes the end of a program definition. All program
definitions must begin with nPRi or nDRi and end
with EP.
Example: PR15 [part A] AC4 VE30 DI10.5 GO EP
<n>EP
EX
Ends Upload All or Load All
Signals the end of a upload all (UA) or load all (LA)
sequence. EX is sent by the SmartDrive to the host
after completing a UA. EX is sent by the host to the
SmartDrive to terminate a LA.
<n>EX
LA
Load All
Sent to the SmartDrive before downloading a long list
of setup parameters and programs. This command
will disable the non-addressed units so that each
setup parameter doesn’t need an address. Must be
followed by an EX to reestablish the daisy chain
communications.
<n>LA
LS
List Programs
Lists number of programs, memory usage, and the
current available memory of the SmartDrive. Just like
Edit/List from the keypad.
<n>LS
OC
Original Configuration
Returns the FLASH to its original factory-default
state. The command buffer is cleared, all programs
are erased, and all configuration settings are
returned to their default values
Can be done with keypad, pressing sequentially.
.
➝
DEL (decimal, right arrow, delete)
<n>OC
PR
Define Program
Starts a program definition. Just like the DR
command, but writes the SmartDrives non-volatile
EEP ROM memory.
Example: PR25 AC.1 VE5 DI10 GO EP (uses only a
program number).
Example: PR25 [P/N 170-001] AC.1 VE5 DI10 GO
EP (uses optional program name).
<n>PRi
Содержание B8961
Страница 111: ...109 Chapter 7 Programming with Serial Communication...
Страница 132: ...B8961 and B8962 User Manual 130...
Страница 136: ...B8961 and B8962 User Manual 134 B8961 and B8962 Hardware Connections...
Страница 137: ...135 Chapter 8 Hardware Reference B8961 and B8962 Input and Output Schematics...
Страница 138: ...B8961 and B8962 User Manual 136 Connecting IDC Limit Switches to the B8961 2...
Страница 156: ...B8961 and B8962 User Manual 154...