Chapter 4 - Configuring Your System
This option is used to select acceleration (and deceleration) units.All acceleration
and deceleration values specified in the system will be expressed in these units.
You can specify acceleration as a rate,or in time-to-accelerate to full speed.
1.
Use
ß
and
à
keys to select an axis.
2.
Use the
áâ
and ENTER keys to select acceleration units from the list:
• sec (time to reach top speed)
• (DIST units)/sec
2
• rps
2
(motor Revolutions Per Sec
2
)
This parameter limits the top speed of your motor. Depending on the application,
you may want to limit the speed of your control to prevent accidental damage to
your mechanics. For example,in a leadscrew driven system, exceeding the “critical
speed”will damage the leadscrew or ballscrew.
1.
Use
ß
and
à
keys to select an axis.
2.
Use the numeric k eys to set the maximum velocity in VEL units.
EDIT
SETUP MECH VMAX
Maximum Velocity [MV]
Default:50 (velocity units)
- - Axis One Max Vel. -
ßá
50.0 inch/sec
âà
EDIT
SETUP MECH ACCEL
Acceleration Units [AU]
Default:sec
- Axis One Accel. Units
ßá
sec
âà
Configuring Acceleration Maximum [AM]
Default: 0.002 (acceleration units)
Range:
0.002 - 99999999 (acceleration units)
Acceleration maximum sets a maximum acceleration and deceleration limit for pro-
grammed move profiles in the cur rent acceleration units.Programmed accelera-
tions and decelerations for moves will be limited by this parameter (analogous to
VMAX for velocity).Regardless of acceleration units,the absolute maximum accel-
eration is 0.002 seconds.
1.
Use the
ß
and
à
keys to select an axis.
2.
Use numeric keys to enter a new acceleration maximum in the same units
selected in the SETUP > MECH > ACCEL menu and press ENTER then ESC to
register.
EDIT
– Axis One Max Accel
–
ß
0.002 sec
à
> SETUP > MECH > AMAX
27
Содержание B8961
Страница 111: ...109 Chapter 7 Programming with Serial Communication...
Страница 132: ...B8961 and B8962 User Manual 130...
Страница 136: ...B8961 and B8962 User Manual 134 B8961 and B8962 Hardware Connections...
Страница 137: ...135 Chapter 8 Hardware Reference B8961 and B8962 Input and Output Schematics...
Страница 138: ...B8961 and B8962 User Manual 136 Connecting IDC Limit Switches to the B8961 2...
Страница 156: ...B8961 and B8962 User Manual 154...