RA Indoor Unit
SiBE121135
156
Operation Manual
INTELLIGENT EYE Operation
90˚
55˚
7m
55˚
7m
[Example]
Normal operation
When no one is in the room
Back to normal operation.
When someone is in the
room
Someone is back in the
room
• The air conditioner is in normal
operation while the sensor is
detecting the movement of people.
20 minutes after, start
energy saving operation.
• The set temperature is shifted in
±2˚C steps.
• The air conditioner will return to
normal operation when the sensor
detects the movement of people
again.
INTELLIGENT EYE operation is useful for energy saving
• If no presence detected in the room for 20 minutes, the energy saving operation will start.
• This operation changes the temperature –2˚C in HEAT / +2˚C in COOL / +1˚C in DRY operation from set temperature.
When the room temperature exceeds 30˚C, the operation changes the tempe1˚C in COOL / +1˚C in DRY operation from set
temperature.
• This operation decreases the airflow rate slightly in FAN operation only.
NOTE
Notes on INTELLIGENT EYE operation
Energy saving operation
• Application range is as follows.
Vertical angle 90˚
(Side view)
Horizontal angle 110˚
(Top view)
•
Sensor may not detect moving objects further than 7m away. (Check the application range.)
• Sensor detection sensitivity changes according to indoor unit location, the speed of passersby, temperature range, etc.
• The sensor also mistakenly detects pets, sunlight, fluttering curtains and light reflected off of mirrors as passersby.
• INTELLIGENT EYE operation will not go on during POWERFUL operation.
•
NIGHT SET mode will not go on during use of INTELLIGENT EYE operation.
CAUTION
• Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor’s detection area. This sensor can detect undesirable objects.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
Содержание Super Multi NX 3MKS50E3V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439...