SiBE121135
RA Indoor Unit
Operation Manual
145
FVXG25/35/50K2V1B
To start operation
• Each pressing of the button advances the mode setting in sequence.
AUTO
DRY
COOL
HEAT
FAN
2.
Press .
Display
To stop operation
Press again.
NOTE
MODE
Notes on each operation mode
• This mode is valid for fan only.
1.
Press and select an operation mode.
The air conditioner operates with the operation mode of your choice.
From the next time on, the air conditioner will operate with the same operation
mode.
AUTO · DRY · COOL · HEAT ·
FAN Operation
• “ ” is displayed on the LCD.
• The OPERATION lamp lights green.
• “ ” disappears from the LCD.
• The OPERATION lamp goes off.
HEAT
COOL
DRY
AUTO
FAN
• Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in
lower outdoor temperatures. If the heating effect is insufficient, it is recommended to use another heating appliance in
combination with the air conditioner.
• The heat pump system heats the room by circulating hot air around all parts of the room. After the start of HEAT operation, it
takes some time before the room gets warmer.
• In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, the system switches
into defrosting operation to take away the frost.
• During defrosting operation, hot air does not flow out of indoor unit.
• This air conditioner cools the room by releasing the heat in the room outside.
Therefore, the cooling performance of the air conditioner may be degraded if the outdoor temperature is high.
• When the outdoor temperature is lower than 10˚C, do not use COOL operation. If the operation is used when the outdoor
temperature is lower than 10˚C, the protective function of the main unit works and this disables the operation.
• The computer chip works to rid the room of humidity while maintaining the temperature as much as possible. It automatically
controls temperature and airflow rate, so manual adjustment of these functions is unavailable.
• In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the room and outside
temperatures and starts the operation.
• The system automatically reselects setting at a regular interval to bring the room temperature to user-setting level.
Содержание Super Multi NX 3MKS50E3V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439...