Indoor Unit
Printed Circuit Board Connector Wiring Diagram
41
2. Indoor Unit
2.1
FTXG25/35/50JV1BW(A)
Connectors and
Other Parts
[A1P]: Control PCB
[A2P]: Signal Receiver / Display PCB
[A3P]: INTELLIGENT EYE Sensor PCB
1) S21
Connector for centralized control (HA)
2) S25
Connector for INTELLIGENT EYE sensor PCB
3) S32
Indoor heat exchanger thermistor
4) S41
Connector for swing motors
5) S42
Connector for reduction motor (front panel mechanism) and limit switch
6) S46
Connector for signal receiver / display PCB
7) S200
Connector for fan motor
8) H1, H2, H3,
FG
Connector for terminal board
9) JB
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
∗
Refer to page 418 for detail.
10) LED A
LED for service monitor (green)
11) F1U
Fuse (3.15 A, 250 V)
12) V1
Varistor
1) S51
Connector for control PCB
2) S52
Connector for room temperature thermistor
3) S1W
Forced cooling operation [ON/OFF] button
4) H1P
LED for operation (multi-color)
5) H2P
LED for INTELLIGENT EYE (green)
6) JA
Address setting jumper
∗
Refer to page 415 for detail.
1) S36
Connector for control PCB
Содержание Super Multi NX 3MKS50E3V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439...