2.1.6 Temperature Setting
Temperature Setting
To change the temperature setting
Press .
• The displayed items on the LCD will change whenever either one of the buttons is pressed.
COOL operation
18-32˚C
10-30˚C
18-30˚C
The temperature setting is not variable.
Operating conditions
MODE
Operating conditions
If operation is continued out of this range
Outdoor temperature :
Indoor temperature : 18-32˚C
Indoor humidity : 80% max.
Outdoor temperature : <2MXS> –10-24˚C
<3/4/5MXS> –15-24˚C
<RXG> –15-24˚C
Indoor temperature : 10-30˚C
• A safety device may work to stop the operation.
Outdoor temperature :
Indoor temperature : 18-32˚C
Indoor humidity : 80% max.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
Press to raise the temperature and press to lower the
temperature.
AUTO operation
DRY or FAN operation
HEAT or RADIANT
operation
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the outdoor
unit only.)
• Condensation may occur on the indoor unit and drip.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.
<2/3/4/5MXS> 10-46˚C
<RXG> 10-46˚C
<2/3/4/5MXS> 10-46˚C
<RXG> 10-46˚C
Recommended temperature setting
• For cooling: 26-28˚C
• For heating: 20-24˚C
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks.
Notes on the operating conditions
• The outdoor unit consumes some power to have its electric components work even while it is not operating.
Connecting outdoor unit RXG25/35: 1-15W
Other outdoor units: 15-20W
The outdoor unit consumes 40 to 55W of power at the time of compressor preheating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
• Use the air conditioner in the following conditions.
COOL
HEAT or
RADIANT
DRY
Содержание Super Multi NX 3MKS50E3V1B
Страница 187: ...SiBE121135 RA Indoor Unit Operation Manual 175 2 1 17 Quick Reference FTXG25 35 50JV1BW A Quick Reference...
Страница 188: ...RA Indoor Unit SiBE121135 176 Operation Manual FTXS20 25K2V1B CTXS15 35K2V1B Quick Reference...
Страница 189: ...SiBE121135 RA Indoor Unit Operation Manual 177 FVXG25 35 50K2V1B Quick Reference...
Страница 246: ...SA Indoor Unit SiBE121135 234 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 413: ...SiBE121135 Outdoor Unit 80 90 Class Removal Procedure 401 7 Remove the sound blanket inner Step Procedure Points R10439...