4.11 Selecting the PLL mode
The PLL menu is obtained with MENU DIL, lever 3 ON (DOWN) and all other levers
UP (OFF
)
.
SEL
Display
Comments
2
PLL Off, 1 or 2
Select the PLL mode from Off, Sdi 1 or Sdi 2 with the
shaft encoder.
Note:
Details of the PLL function may be found in the Introduction and the Statesman chapter.
4.12 Selecting the re-sampling mode
The re-sampling menu is obtained with MENU DIL, lever 3 ON (DOWN) and all other
levers UP (OFF
)
.
SEL
Display
Comments
3
Resamp On, Off or n/a
Re-sampling is applicable for DIP2RS cards only.
4.13 The operating mode
TANDEM-110 does not support modes other than mode 1. For this reason the MODE
change function will be disabled. It is documented here for completeness only. The menu
is obtained with Menu lever 3 ON (DOWN) and all other levers UP (OFF
)
.
SEL
Meaning
Comments
0
Display present mode
Display will be MODE = 1
1
Select mode
Disabled on TANDEM-110. Display will be 0
2 - 15
Not used at present
4.14 Miscellaneous functions
Firmware version number
The TANDEM-110 firmware version number is obtained with Menu lever 6 ON
(DOWN), all other levers UP (OFF
)
and the SEL switch in position C.
SEL
Display
Comments
D
TANDEM 6.12
TANDEM firmware version number
Note:
SEL position C and menus beyond D provide information for Crystal Vision technical
staff only.