Crystal Vision
Problem solving
TANDEM-110 User Manual R1.8
97
07/07/2010
SEL
No.
Display
Video input status examples and comments
7
TRS_xx_yy
Codes: Ok, Er, ni
SDI1 & SDI2 Demux Channel TRS Status.
TRS errors may result in corrupted audio data.
Example: TRS_ni_Ok, SDI1 is not present, SDI2 does not
have a TRS error. Er is displayed for erroneous TRS values.
8
Vd_nLC_nLC
Codes: 5, 6, L, C,
x, ni
SDI1 & SDI2 Demux Channel Chrominance and Luminance
Status.
n - video standard, 6 for a 625 input and 5 for a 525 input
L - Active Luminance is shown by ‘L’ or ‘x’ for dark or near
dark values – signal peaks below 12.5% of Peak White.
C - Active Chrominance is shown by ‘C’ or ‘x’ for
monochrome or near monochrome values – chroma peaks less
than 12.5% Saturation.
Example: Vd_6LC__ni, SDI 1 is 625 with significant
Luminance and Chrominance content, but SDI2 is absent.
Note:
The continued presence of ‘x’ values for Chrominance or Luminance may indicate an
error condition, such as no picture or lack of colour.