Too much air in the
system.
Vent the system.
Deviation in the flow
or return
temperature sensor.
Check that the sensors are
working; take the sensors
out* and
measure the resistance
with a multimeter at room
temperature (20 - 25°C);
the sensor is working
properly if the resistance is
between 12 and 15 kOhm.
[E][2]
Return
temperature is
higher than the
flow
temperature.
Insufficient water.
Check the water level and
check for leaks.
No through flow.
Check that the pump is
working; turn the spindle
with a screwdriver,
if that works but the pump
still does not respond,
check the wiring;
that is in order the pump is
faulty.
Too much air in the
system.
Vent the system.
Sensors not wired
correctly.
Check the wiring between
sensors and control unit.
Pump operating in
wrong direction.
Check wiring from and to
control unit.
Flow and return
connections
crossed.
Flow and return
connections.
Deviation in the flow
or return
temperature sensor.
Check that the sensors are
working; take the sensors
out* and
measure the resistance
with a multimeter at room
temperature (20 - 25°C);
the sensor is working
properly if the resistance is
between 12 and 15 kOhm.
page 45
Error
code
Description
Possible cause
Check / solution
[E][3]
Control unit or earth
fault.
Mains supply not
correctly earthed.
Control unit faulty.
Check that the power supply from the
switch spur is properly earthed;
if that is the case the control unit is faulty.
[E][4]
More than 5 start
attempts
without any flame
formation.
No ignition spark.
Check:
•
the connection between the
ignition wire and the ignition trafo;
Содержание Avanta 12v
Страница 15: ...fig 05 Mounting the Avanta 59970 LT GB W7H 002 page 8 2 3 Water side connections 2 3 1 Water flow ...
Страница 34: ...fig 16 Connecting external controls R000158 A page 18 ...
Страница 35: ......
Страница 63: ...fig 42 Read out settings LT AL W7H 000 046 ...
Страница 68: ...fig 43 Change parameters in service level LT AL W7H 000 047 ...
Страница 70: ...fig 44 Change boiler output LT AL W7H 000 048 ...
Страница 87: ...fig 59 Assembling the boiler 59970LTGBW7H031 page 44 4 ERRORS 4 1 General ...
Страница 96: ......
Страница 99: ...fig 62 Exploded view Remeha Avanta 59970EVGBW7H010 ...
Страница 108: ...page 60 ...
Страница 109: ...page 61 ...