[E][6]
Unwanted flame
formation.
Ignition Unit.
Faulty ignition unit, replace ignition unit.
Control unit.
Faulty control unit, replace control unit.
[E][7]
No water in the
boiler or the pump
is not working.
Insufficient water.
Check the water level and check for leaks.
No through flow.
Check that the pump is working; turn the
spindle with a screwdriver,
if that works but the pump still does not
respond, check the wiring;
that is in order the pump is faulty.
Too much air in the
system.
Vent the system.
Pump operating in wrong
direction.
Check wiring from and to control unit.
Pump not running.
Check wiring, connections and pump.
[E][8]
Fan fault.
Fan is not working.
Check:
•
fan function;
•
fan wiring and connection.
Fan does not stop.
Check:
•
fan function;
•
fan wiring and connection;
•
excess chimney draught.
page 46
Error
code
Description
Possible cause
Check / solution
[E][9]
No water in the
boiler or the pump
is not working
Insufficient water in
central heating
system
Check the minimum water pressure, read off
the gauge and check for leaks
(ie. Expansion vessel)
Refill the central heating system
Bleed the central heating system
Reset boiler
Failure water
pressure switch
Contact installer
[E][1][0]
No through flow
during venting
cycle.
Insufficient water.
Check the water level and check for leaks.
Too much air in the
system.
Vent the system.
No through flow.
•
Check that the pump is working; turn
the spindle with a screwdriver,
if that works but the pump still does
not respond, check the wiring;
if that is in order the pump is faulty;
•
Open the radiator valves.
Содержание Avanta 12v
Страница 15: ...fig 05 Mounting the Avanta 59970 LT GB W7H 002 page 8 2 3 Water side connections 2 3 1 Water flow ...
Страница 34: ...fig 16 Connecting external controls R000158 A page 18 ...
Страница 35: ......
Страница 63: ...fig 42 Read out settings LT AL W7H 000 046 ...
Страница 68: ...fig 43 Change parameters in service level LT AL W7H 000 047 ...
Страница 70: ...fig 44 Change boiler output LT AL W7H 000 048 ...
Страница 87: ...fig 59 Assembling the boiler 59970LTGBW7H031 page 44 4 ERRORS 4 1 General ...
Страница 96: ......
Страница 99: ...fig 62 Exploded view Remeha Avanta 59970EVGBW7H010 ...
Страница 108: ...page 60 ...
Страница 109: ...page 61 ...