page 33
2.10.7 Adjust the boiler according to the system
The operating parameters of the Remeha Avanta have been factory set to suit most
systems. However it is possible to adjust some of the parameters to enable the
Remeha Avanta to operate more efficiently to match specific system designs and
site conditions. These parameters are split into two specific sections:
1. User level - Parameters
[P][1]
to
[P][6]
; can be changed by the user to suit
CH and DHW comfort conditions
2. Service level -
[P][1][7]
to
[d][F]
; must only be changed by Remeha approved
Engineer after consultation with the system designer.
How to change the parameters at user level can be read on the "Short
reference card" provided and therefore will not be detailed in this Installation and
Service manual.
2.10.8 Changing the parameters at service level (with access code)
To avoid non authorised adjustments, some parameter settings can only be changed
once the special access code
[1][2]
has been entered. This code may only be used
by qualified installers.
The following settings can be changed at user and service level:
Codes in
display
Description
Setting range and notes
where applicable
Factory settings
12v
15v
18v
24v
30v
[P][1]
T
set
flow
20 - 85°C
75°C
6)
[P][2]
T
set
DHW
40 - 65°C
55°C
[P][3]
Boiler regulation
0 = CH
off
and DHW
off
1 = CH
on
and DHW
on
2 = CH
on
and DHW
off
3 = CH
off
and DHW
on
2
[P][4]
Eco or comfort setting
0 = comfort setting
1 = eco mode
2)
2 = regulated by controller
2
[P][5]
Anticipated current
0 = no anticipated current
for thermostat on/off
1 = anticipated current for
thermostat on/off
0
Содержание Avanta 12v
Страница 15: ...fig 05 Mounting the Avanta 59970 LT GB W7H 002 page 8 2 3 Water side connections 2 3 1 Water flow ...
Страница 34: ...fig 16 Connecting external controls R000158 A page 18 ...
Страница 35: ......
Страница 63: ...fig 42 Read out settings LT AL W7H 000 046 ...
Страница 68: ...fig 43 Change parameters in service level LT AL W7H 000 047 ...
Страница 70: ...fig 44 Change boiler output LT AL W7H 000 048 ...
Страница 87: ...fig 59 Assembling the boiler 59970LTGBW7H031 page 44 4 ERRORS 4 1 General ...
Страница 96: ......
Страница 99: ...fig 62 Exploded view Remeha Avanta 59970EVGBW7H010 ...
Страница 108: ...page 60 ...
Страница 109: ...page 61 ...