Eq. Length of 45°
elbow
LT W6H 000 032
0.65
table 03 Maximum pipe lengths for flue duct and air supply in room sealed
application
page 15
For flue installations not covered by this booklet, please contact our
Technical Enquires: 0118 974 3070.
2.5.3 Connecting the flue terminal and air supply
•
Check the depth of the wall and cut the terminal to suit - taking note of the
cutting instructions supplied with it.
•
Core drill a 125 mm Ø hole in the wall, fit the rubber closure plate at the exit
end and slide the terminal through the wall until the closure plate is clear of
the outer edge of the wall - pull back the terminal till the closure plate is flush
then fit inner wall closure to secure.