Check that all electrical connections, including the earth connection, have
been made correctly.
•
Check the electrical connections to the thermostat and other external controls.
•
Check that the flue-gas and air-supply connections are sealed.
fig. 36 Check electrical connections and thermostat
R000164-A
page 28
3.
Switching the boiler on and setting the controls
•
Replace the fuse and switch on the 230 V power supply.
•
Set the controls to heat demand.
•
When 230v power is first applied to the boiler or after the 230v supply has
been isolated for maintenance the boiler will not start until it has fully
completed its venting cycle - this will take about 3 minutes during which time
the display will show
[F]:[X][X]
alternating
with
[P]:[X][X]
(where
[X][X]
displays the software version number). This is
not a fault, please wait until the cycle is finished. Provided no error codes