The boiler should be mounted on a suitable vertical wall which is able to
support the weight of the boiler.
•
The boiler should be mounted in a room which, even during severe cold
weather, remains frost-free, or frost protection controls MUST be fitted.
•
If the boiler is to be installed in a timber framed building, please refer to British
Gas publication: 'Guide for Gas Installations in Timber frame Housing',
reference DM2.
•
Make sure the boiler and any open connections are protected from building
dust etc. during the installation.
•
There must be a 3 amp fused switched spur within 1 m of the boiler.
•
Provision must be made for the condensate discharge.