3 Switch Unit (SU1)
LED Name
Color
States
Alarm
RED
ON
when SU1 itself has a fault.
BLINKING
during the following operations:
1) Manually set to forced blinking.
2) If also yellow LED is blinking, the card/NE has reached
shutdown state after "esw-shutdown" command and can be
removed from NE or power can be switched off.
OFF
otherwise.
Alarm
YELLOW
ON
when online and SU1 detects some non-critical fault.
BLINKING
during the following operations:
1) Boot-up sequence.
2) Inventory create.
3) Inventory (backup) restoration.
4) Manually set to forced blinking.
5) If also red LED is blinking, the card/NE has reached
shutdown state after "esw-shutdown" command and can be
removed from NE or power can be switched off.
OFF
otherwise.
OnLine
GREEN
ON
when SU1 is online (it is “up” meaning successful boot-up
sequence
fi
nished and and the switch matrix is switching).
Note that online NE may still contain errors.
BLINKING
when manually set to forced blinking.
OFF
otherwise.
Power
GREEN
ON
when NE power is ON and undervoltage not detected.
BLINKING
Power supply failure.
OFF
otherwise.
8600 Smart Routers
76.8670-40128B
8665 Smart Router FP7.0 Reference Manual
© 2015 Coriant.
44