C200H AC Servo Manual
34
2. Ground handling
To avoid electromagnetic interference problems, please ground as below.
1) Grounding of servo motor housing
Please connect the grounding terminal of the servo motor with the grounding terminal PE of the
servo driver and ground the PE terminal reliably to reduce the potential electromagnetic
interference problem.
2) Encoder Cable Shield Grounding
Please ground both ends of shield layer of motor encoder cable.
4.7.2 How To Use A Noise Filter
In order to prevent the interference of the power cable and weaken the influence
of the servo driver on other sensitive devices, please select a corresponding noise
filter at the input end of power supply according to the input current. Meanwhile,
please install the noise filter at the power cable of peripheral device if needed.
Please observe the following precautions when installing and wiring the noise filter
so as not to weaken the actual use effect of the filter.
Please separate the input and output cables of the noise filter, and do not put both into the
same pipe or tie them together.
Pic 4.14 Example Diagram Of Noise Filter Input And Output Cables
The cable of the outer box connection used for grounding should be more
than 3.5 mm² of coarse wire, and braided copper cables are recommended.
When using the noise filter, please observe the precautions described in the following
"use method of noise filter".
Содержание C200H Series
Страница 1: ...https en coolmay com ...
Страница 2: ...C200H AC Servo Manual https en coolmay com ...
Страница 43: ...C200H AC Servo Manual 36 Pic 4 17 Ground Connection Handling Of Noise Filter ...
Страница 52: ...C200H AC Servo Manual 45 5 2 2 Speed Mode Wiring 三相 Pic5 4 Speed Mode Wiring ...
Страница 55: ...C200H AC Servo Manual 48 5 3 2 Torque Mode Wiring Pic5 6 Torque Mode Wiring ...
Страница 64: ...C200H AC Servo Manual 57 No 4 alarm ...
Страница 119: ...C200H AC Servo Manual 112 Version 22 51 ...